NRIC MAGNET/He-CTF Operating Parameters
| Parameter | Value | 
|---|---|
| Coolant gas | N2 or He | 
| Maximum pressure | 20 bar | 
| Maximum gas temperature | 650 °C | 
| Maximum test article temperature | 750 °C | 
| Maximum N2 flow rate | 0.938 kg/s | 
| Maximum He flow rate | 0.134 kg/s | 
| Maximum air pressure | 8.5 bar | 
| Maximum air flow | 0.08 m3/s (actual discharge flow at compressor inlet conditions) | 
| Maximum power available for core heating | 250 kW | 
| Maximum power available for gas heating | 80 kW / gas stream | 
| Test article containment size | 1.5 m x 1.5 m x 3 m (length) | 
| Data acquisition and control | Configurable with Opto 22 hardware | 